Download ASHRAE 2000 HVAC Systems and Equipment Handbook PDF

Read or Download ASHRAE 2000 HVAC Systems and Equipment Handbook PDF

Best technique books

Trauma--an engineering analysis: with medical case studies investigation

The aim of this e-book is to collect specialists from the scientific and engineering fields during which trauma acts as a fulcrum in figuring out the engineering method of scientific situations. The emphasis of this e-book is at the retrospective learn of scientific eventualities as obvious from the engineering standpoint.

Career Development in Bioengineering and Biotechnology: Roads Well Laid and Paths Less Traveled

Bioengineering and biotechnology are exploding—the variety of occupation possibilities is anticipated to extend two times as quick as for different technology and engineering fields over the subsequent decade. Bioengineers and biotechnologists have huge, immense strength to fulfill employment wishes starting from conventional careers in technological know-how and engineering via a number of different profession pathways.

The electrical engineering handbook. Systems, controls, embedded systems, energy, and machines /Third ed

In variants spanning greater than a decade, Engineering guide stands because the definitive connection with the multidisciplinary box of electric engineering. Our wisdom maintains to develop, and so does the guide. For the 3rd variation, it has extended right into a set of six books conscientiously inquisitive about a really expert zone or box of analysis.

Extra info for ASHRAE 2000 HVAC Systems and Equipment Handbook

Sample text

The design engineer should keep the owner and facility engineer informed, whenever possible, about the HVAC analysis and system selection. Space criteria should satisfy both the architect and the owner or the owner’s representative. Where designers cannot negotiate a space large enough to suit the installation, the judgement of the owners should be called upon. Although few buildings are identical in design and concept, some basic criteria apply to most building and help allocate space that approximates the final requirements.

Components are matched and assembled to achieve specific performance objectives. These limitations make the manufacture of low cost, qualitycontrolled, factory-tested products practical. For a particular kind and capacity of unit, performance characteristics vary among manufacturers. All characteristics should be carefully assessed to ensure that the equipment performs as needed for the application. Several trade associations have developed standards by which manufacturers may test and rate their equipment.

Many local jurisdictions require separation of refrigeration and fuel fired equipment. It is often economical to locate the refrigeration plant at the top of the building, on the roof, or on intermediate floors. These locations closer to the load allow the equipment to operate at a lower pressure. The electrical service and structural costs will be greater, but these may be offset because the energy consumption and the condenser and chilled water piping cost may be less. The boiler plant may also be placed on the roof, which eliminates the need for a chimney through the building.